Baker Instruments DX12
12kV Static Motor & Winding Analyser
|
VIEW DATA SHEET
|
|
BAI-DX12/RLC | /RLC Capabilities |
|
|
|
Baker Instruments DX12 BAI-DX12 12kV Static Motor & Winding Analyser Input power: 100 - 240 Volts 50/60 Hz Universal supply The SKF Static Motor Analyser Baker DX unit offers more capabilities to analyze all insulation and motor circuits in AC and DC motors, generators and coils. These instruments can offer Insulation Resistance (IR), Polarization Index (PI), Dielectric Absorption (DA), DC HiPot/Step Voltage and Surge tests to evaluate all the insulation in motors and coils. The motor circuit can also be analyzed utilizing Resistance,ments. Impedance, Capacitance, Phase Angle and Dissipation Factor/Quality Factor measurements. DX benefits *4 to 40 kV voltage testing capability to test fractional HP motors to 40 megawatt generators *High and low voltage testing capability in one unit to test the motor circuit and all the insulation *Intuitive graphical user interface with touch screen *USB printer interface to quickly print results *Coil mode quickly analyze coils and store all data *Impulse mode allows the operator to quickly apply voltage when testing coils and DC motors *Fully test DC motors *Push to Test (PTT) lock to hold voltage during DC tests *Modular design to meet your testing needs *Internal test storage capacity 2 GB *The Baker DX is the smallest, lightest 12 kV surge tester on the market Surge Capacitor size (nF): 40 Surge energy: 2,88 J Short circuit current: 600 A 65 H load voltage: 12 kV Surge voltage accuracy: 11% DC tests Voltage accuracy: 3% Maximum resistance: > 500 G Accuracy: 5% Minimum resistance: 10 MOhm Maximum output current: 3 mA Over-current trip: 1,4 mA Resistance Source voltage, maximum: 3,9 V Source current: 600 mA 10 000 to 200 000 : 3% accuracy 100 to 10 000 : 3% accuracy 0,2 to 100 : 2% accuracy 0,002 to 0,2 : 4%, 1 mOhm accuracy Capacitance Source voltage, maximum: 3,9 V Source current, maximum: 600 mA Source frequency: 50 to 4 000 Hz 0,001 to 2,6 F at 4 000 Hz: 3% accuracy 2,6 to 26 F at 4 000 Hz: 5% accuracy Inductance Source voltage, maximum: 3,9 V Source current, maximum: 600 mA Source frequency: 50 to 4 000 Hz 160 to 5 000 mH at 60 Hz: 3% accuracy 0,5 to 160 mH at 60 Hz: 2% accuracy 0,05 to 0,5 mH at 60 Hz: 3% accuracy Impedance Source voltage, maximum: 3,9 V Source current, maximum: 600 mA Source frequency: 50 to 4 000 Hz 0,15 to 10 000 at 60 Hz: 2% accuracy 0,01 to 0,15 at 60 Hz: 3% accuracy Phase accuracy at 60 Hz: <2 deg. |
|
|
58.42
cm
|
48.26
cm
|
20.32
cm
|
27.27
kg
|
| | | |
|
|
N/A
Currently not available for sale |
Need
Configuration Assistance? Call our experienced Sales Staff.
|
|
|